Detail >>
Detail >>
Advance Search
ADSL Products
- ADSL USB Modem
- ADSL Router 1 port
- ADSL Router 4 ports
- ADSL Wireless Router
- USB Wireless LAN
- DSL Tester
- Wireless Network Camera

ISDN Products
- Network Terminator:NT1
- Network Terminator +
  Terminal Adaptor:NT+TA
- ISDN USB Modem
- ISDN Digital Phone

GSM Gateways
- Analog-GSM
- ISDN-GSM
- VoIP-GSM
- VTM Pro
- VTM Flex
- GSM3-210
- ECOTELcontrol:C3andC4
- ECOTELcontrol:C6

VoIP Voice Gateway Series
You can also order our products by calling +66 2 219 7231-2
---------------------------------------------------------------------------------------------------------------------------------


Home l support l Contact us
Copyright©2006 AFG Asia Satellite Co.,Ltd. All rights reserved.
---------------------------------------------------------------------------------------------------------------------------------
http://www.EUROXI.com
Home l support l Contact us l News & Events
Version  Thai : English 
 Select Model   
Electronic Ballast
-----------------------------------------------------------------------------------------------
Leuchten : 36L220MN-PFC
Type : Power Factor Correction
- Ideal for the area with a high switching 
  frequency
- Can be use with automatic lighting control 
  system
- Energy saving or budged saving projects 
  (One is from the electrical cost)
- Airport Terminal & Railway Stations that are
  operated overnight
- Department stores, Supermarket
- Medical/Science Labs, Hospitals, Clinics that 
  need stability of lights for analysis
- Modern office building
- High-class business company
- House-light in theatre or Cinema
- Sound Studio, Cine/Television Studio
- Production Facilities with long lighting duty time,
  rotating machinery, hazardous areas, low 
  appliance power
Technical Specification
Input Current 0.16 ampare
Referance Voltage 220V AC
Operation Voltage 176-264 Volt
Main Frequency 50/60Hz
Operation Frequency 35kHz
Power Factor > 0.99
Dimension L x W x H 222.5 x 30 x 25mm.
Lamp wiring Range max. x 3m. from ballast
Temperature Range to ignition fluorescent lamp : -5C to +50C
Total Harmonic Distortion THD < 10%
Maximum case temperature Tc 70C
Hum or noise level under-audible
Lamp start within 2sec. optimum filament pre-heating
Leuchten : 36L220MN36
Type : Medium(MN-36) 36W x 1
- Ideal for the area with a high switching 
  frequency
- Can be use with automatic lighting control 
  system
- Energy saving or budged saving projects 
  (One is from the electrical cost)
- Airport Terminal & Railway Stations that are
  operated overnight
- Department stores, Supermarket
- Medical/Science Labs, Hospitals, Clinics that 
  need stability of lights for analysis
- Modern office building
- High-class business company
- House-light in theatre or Cinema
- Sound Studio, Cine/Television Studio
- Production Facilities with long lighting duty time,
  rotating machinery, hazardous areas, low 
  appliance power
Technical Specification
Input Current 0.16 ampare
Referance Voltage 220V AC
Operation Voltage 176-264 Volt
Main Frequency 50/60Hz
Operation Frequency 35kHz
Power Factor > 0.97
Dimension L x W x H 222.5 x 30 x 25mm.
Lamp wiring Range max. x 3m. from ballast
Temperature Range to ignition fluorescent lamp : -5C to +50C
Total Harmonic Distortion THD < 15%
Maximum case temperature Tc 70C
Hum or noise level under-audible
Lamp start within 2sec. optimum filament pre-heating
Leuchten : 36L220MNB36
Type : Medium(36x1)
- Ideal for the area with a high switching 
  frequency
- Can be use with automatic lighting control 
  system
- Energy saving or budged saving projects 
  (One is from the electrical cost)
- Airport Terminal & Railway Stations that are
  operated overnight
- Department stores, Supermarket
- Medical/Science Labs, Hospitals, Clinics that 
  need stability of lights for analysis
- Modern office building
- High-class business company
- House-light in theatre or Cinema
- Sound Studio, Cine/Television Studio
- Production Facilities with long lighting duty time,
  rotating machinery, hazardous areas, low 
  appliance power
Technical Specification
Input Current 0.16 ampare
Referance Voltage 220V AC
Operation Voltage 176-264 Volt
Main Frequency 50/60Hz
Operation Frequency 35kHz
Power Factor > 0.97
Dimension L x W x H 152 x 42 x 35mm.
Lamp wiring Range max. x 3m. from ballast
Temperature Range to ignition fluorescent lamp : -5C to +50C
Total Harmonic Distortion THD < 15%
Maximum case temperature Tc 70C
Hum or noise level under-audible
Lamp start within 2sec. optimum filament pre-heating
Leuchten : 36L220MNB36 x 2
Type : 36W x 2
- Units is lightweight and relatively simple to
  installation, less wiring and fewer circuit
  components 
- Striation-free operation
- Non flicker when start light-up (ignition) this
  enables the lamps to be switched on/off without
  reducing useful life
- Smooth light because pleasent flicker-free
  light-output (no stroboscopic effects)
- No flashing or flickering of defective lamps in
  the circuit, automatic shutdown of lamps in the 
  event of a detect or at the end of their life
- Useful energy saving :

  : 50% longer lamp-life than system with 
    magnatic ballast
  : Reduction in electric consumption up to 25%
    at constant luminous flux compared with 
    magnatic ballast
  : No heat-radiation that it is reduced load an air 
    conditioning system

- Double-ended covering with mechanical 
  interlock are titles for electric cable connecting
  terminals which is Hi-heat framedetained for 
  electric product
- The electric components are SMD on printed 
  circuit board that is placed completely in the 
  main body 
- Feel free from open load or shorted circuit from
  lamps problem
- Each unit is protected against excessive main 
  voltage & output of lamps
- Non spaces for house-lizard entrance into the 
  ballast 
Technical Specification
Input Current 0.33 ampare
Referance Voltage 220V AC
Operation Voltage 176-264 Volt
Main Frequency 50/60Hz
Operation Frequency 35kHz
Power Factor > 0.97
Dimension L x W x H 176 x 42 x 35mm.
Lamp wiring Range max. x 3m. from ballast
Temperature Range to ignition fluorescent lamp : -5C to +50C
Total Harmonic Distortion THD < 15%
Maximum case temperature Tc 70C
Hum or noise level under-audible
Lamp start within 2sec. optimum filament pre-heating
 Download Leuchten Electronic Ballast Catalog
Emergency Lights
-----------------------------------------------------------------------------------------------
  
Emergency Light
Specifications
- Battery Specifications  :  Size AAA x 4
- Power source              :  90-260V
- Product Dimension      :  60 x 108 x 20mm.
- Weight                      :  108g.

Features
- Emergency automatic light-up
- Rechargeable
- Duration  :  20 hours


 Download Emergency Light Product catalog